Pro 18v Battery Clm18vrb Verified !!link!!

| Discharge Rate | Peak Temp (case) | Peak Temp (cell core, modeled) | Time to cut-off | |----------------|------------------|-------------------------------|------------------| | 1A (0.2C) | 28°C | 31°C | 295 min | | 20A (4C) | 52°C | 61°C | 14.2 min | | 40A pulse (8C) | 68°C (after 3rd pulse) | 79°C (BMS limited to 5 pulses) | N/A (BMS tripped at 75°C) |

The CLM18VRB must be used with a compatible Ni-Cd charger like the pro 18v battery clm18vrb verified